Live Support
+1-800-426-6301Shop By Category
Showing 13 - 24 of 27
-
Standard Features
- Powered by the award winning Doosan Tier 4f electronic engine with full-authority electronic controls for more precise control over the performance of the engine
- Extended service intervals using extended filters and lubricants, up to 500 hours between scheduled service
- Engine operates with Ultra-low Sulphur Diesel fuel
- Fuel/water separator with water-in-fuel sensor and electronic indication
- Large 35 gallon, high density cross-linked polyethylene fuel tank for 8+ hours of use
- Low fuel warning and no fuel shutdown system
- Shut down on low oil pressure and high engine temperature commonly seen listed as (LOP/HET protection)
- 12 volt control and starting circuitry for easy cold weather starting
- Automated glow plug control for cold weather starting
- Large engine Digital Display and Diagnostics module (DDD), this is a multi-function tool to view engine parameters and fault codes
- Automatic 60 second power off delay engine shutdown for turbo protection
- 3 year engine warranty
- Powerful 80kw, AVR and 90kVA alternator with SCR regulation
- Maintenance free, long life single bearing
- Automatic output build-up and protection
- Cable head sensing and output drop compensation system ensures full power is provided to aircraft
- Aircraft cable head interlock circuit
- Wiring and color code in accordance with CE, NFPA and NEC
- 30 ft (9.1 m) AC output cable
- Durable, compact, maneuverable, trailer mounted unit with fifth wheel steering
- Front wheel scrub brake for simplicity
- Weather resistant powder coated sheet metal to prevent corrosion
- Corner lights and stack light
- Large cable trays for easy cable stowage
- Finish: Durable Powder Coat Tronair Blue
- CE marked
- Unit allows simultaneous use of 400 Hz AC and 28.5 VDC
- Powerful 80kw, AVR and 90kVA alternator with SCR regulation and ripple filter for ultra low DC output ripple
- Adjustable peak output current limiting control, 2,000 amp peak, 600 amp continuous output
- 30 ft (9 cm) DC output cable
- Standard Cold Weather Features:
- 120 V Block Heater
- Larger capacity starting battery 900 CCA AGM type battery
- Automatic Glow Plugs
- Insulation package for the engine enclosure and sound dampening
Aircraft Applications: -
Standard Features
- Powered by the award winning Doosan Tier 4f electronic engine with full-authority electronic controls for more precise control over the performance of the engine
- Extended service intervals using extended filters and lubricants, up to 500 hours between scheduled service
- Engine operates with Ultra-low Sulphur Diesel fuel
- Fuel/water separator with water-in-fuel sensor and electronic indication
- Large 35 gallon, high density cross-linked polyethylene fuel tank for 8+ hours of use
- Low fuel warning and no fuel shutdown system
- Shut down on low oil pressure and high engine temperature commonly seen listed as (LOP/HET protection)
- 12 volt control and starting circuitry for easy cold weather starting
- Automated glow plug control for cold weather starting
- Large engine Digital Display and Diagnostics module (DDD), this is a multi-function tool to view engine parameters and fault codes
- Automatic 60 second power off delay engine shutdown for turbo protection
- 3 year engine warranty
- Powerful 80kw, AVR and 90kVA alternator with SCR regulation
- Maintenance free, long life single bearing
- Automatic output build-up and protection
- Cable head sensing and output drop compensation system ensures full power is provided to aircraft
- Aircraft cable head interlock circuit
- Wiring and color code in accordance with CE, NFPA and NEC
- 30 ft (9.1 m) AC output cable
- Durable, compact, maneuverable, trailer mounted unit with fifth wheel steering
- Front wheel scrub brake for simplicity
- Weather resistant powder coated sheet metal to prevent corrosion
- Corner lights and stack light
- Large cable trays for easy cable stowage
- Finish: Durable Powder Coat Tronair Blue
- CE marked
- Standard Cold Weather Features:
- 120 V Block Heater
- Larger capacity starting battery 900 CCA AGM type battery
- Automatic Glow Plugs
- Insulation package for the engine enclosure and sound dampening
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- Currently Viewing 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- Currently Viewing 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- Currently Viewing 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- Currently Viewing 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Looking For Custom Parts?
Contact Us -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- Currently Viewing 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 115 VAC, duplex GFCI weatherproof receptacle with cover on 60 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- Currently Viewing 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 220 VAC, duplex GFCI weatherproof receptacle with cover on 50 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- Currently Viewing 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 220 VAC, duplex GFCI weatherproof receptacle with cover on 50 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- Currently Viewing 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 220 VAC, duplex GFCI weatherproof receptacle with cover on 50 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- Currently Viewing 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications: -
Standard Features
- 2 year Tronair Platinum warranty
- Under 52dB during normal operation, 60dB maximum
- Clean power, low voltage ripple <.2 VDC RMS
- 15 A, 220 VAC, duplex GFCI weatherproof receptacle with cover on 50 Hz Models
- MIL-STD-704F and 18" NEC compliant
- Energy saving thermal control cooling fan
- Low profile fits under most wings
- Sturdy all weather IP54 enclosure with cord hangers
- Long life LED indicator lights that double as diagnostic tool
- 20 ft (6.1 m) output cable with AN2551 aircraft DC connector on Single Models
- 20 ft (6.1 m) and 50 ft (15.24 m) output cable with AN2551 aircraft DC connector on Dual Models (NOTE: 50 ft cable NOT used for starting engines)
- Main disconnect switch
- DC On/Off switch
- Emergency stop switch
- Large 9 in (23 cm) rubber ridgid and lockable swivel casters for easy maneuverability
- Simple to use
- 50 ft (12.2 m) input cable [100 ft (30.5 m) input cable optional] electric plug not included on input cable
- Easy to change multi-volt transformer
- CE marked
- Finish: Durable Powder Coat Tronair Blue
- Input:
- Voltage Range 200-480V +/- 10%+/- 10%
- Power 25 KVA
- Phase 3
- Frequency 50 or 60 Hz
- Output:
- Voltage 28.5 VDC
- Current Limit (Adjustable) 100-2000 max amps DC
- Continuous Power 600 amps at 28.5 VDC
- Starting Power 2000 amps
- Protection:
- Output over/under voltage
- Output over current
- Input phase loss detection, missing phase
- Input over/under voltage
- Input Circuit Breaker 100 amps
- Transformer over temperature
- SCR over temperature
Variants
- 112850D0000 - 50HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112850D0100 - 50HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- Currently Viewing 112850D0200 - 50HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112850S0000 - 50HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112850S0100 - 50HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112850S0200 - 50HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
- 112860D0000 - 60HZ, DUAL SYSTEM, NO OUTPUT CORD
- 112860D0100 - 60HZ, DUAL SYSTEM, 50FT OUTPUT CORD
- 112860D0200 - 60HZ, DUAL SYSTEM, 100FT OUTPUT CORD
- 112860S0000 - 60HZ, SINGLE SYSTEM, NO OUTPUT CORD
- 112860S0100 - 60HZ, SINGLE SYSTEM, 50FT OUTPUT CORD
- 112860S0200 - 60HZ, SINGLE SYSTEM, 100FT OUTPUT CORD
Aircraft Applications:
ATA-24 Ground Support Equipment: Solutions to Maintain Aircraft Electrical Systems
Aircraft electrical power systems are essential for maintaining and servicing aircraft electrical systems while they are on the ground. The ATA-24 aircraft electrical power category of equipment includes tools and devices designed to provide power, support battery maintenance, test electrical systems, and ensure the overall operational readiness of an aircraft's electrical components. Compliance with ATA-24 specifications, which refer to the aircraft's electrical power system, is crucial for maintaining the safety and efficiency of these operations.
At Tronair, we offer an excellent selection of aircraft electrical power systems tailored to meet the stringent requirements of modern aircraft maintenance. Our product range includes ground power units (GPUs), battery carts and chargers, and solid-state rectifiers. Each product is engineered to deliver reliable performance, ensuring your aircraft's electrical systems are properly maintained and ready for operation. Our commitment to quality and innovation makes us a trusted partner in the aviation industry, supporting safe and efficient ground operations worldwide.
Check Out the Tronair ATA-24 Lineup
Want to know more about our aircraft electrical power systems? At Tronair, we offer high-quality solutions that adhere to ATA-24 standards, including ground power units (GPUs), solid-state rectifiers, battery carts, and chargers. Let's take a closer look at what this equipment can do.
Ground Power Units (GPUs)
Ground Power Units (GPUs) are critical aircraft electrical power components. They supply external power to aircraft while on the ground, ensuring their electrical systems remain operational without depleting their batteries. External power is crucial for running onboard systems, performing pre-flight checks, and performing maintenance tasks.
-
Pre-Flight Preparations: GPUs provide the power to run diagnostic checks and ensure all electrical systems function properly before a flight.
-
Maintenance Operations: During routine maintenance or repairs, GPUs power various aircraft systems, allowing technicians to work without relying on the aircraft's internal power.
-
Reducing Engine Use: Using a GPU prevents the aircraft's auxiliary power unit (APU) from running, saving fuel and reducing wear and tear on the aircraft's engines.
Battery Carts and Chargers
Battery carts and chargers are designed to maintain and service aircraft batteries, integral to an aircraft's electrical systems. These units ensure that batteries are always charged and ready for use, supporting regular operations and emergency power needs.
-
Battery Charging and Maintenance: Battery carts and chargers keep aircraft batteries in optimal condition, ensuring they are fully charged and operational when needed.
-
Routine Checks: Regular battery maintenance prevents unexpected power failures and ensures reliable performance.
-
Emergency Readiness: Properly maintained batteries are essential for emergency situations, providing backup power if primary systems fail.
Solid-State Rectifiers
Solid-state rectifiers are an integral part of aircraft electrical power systems. They are designed to convert AC (alternating current) to DC (direct current) power, which most aircraft systems require. Rectifiers ensure a stable and reliable power supply to the aircraft's electrical systems during ground operations.
-
Power Conversion: Solid-state rectifiers convert AC power from ground power sources into the DC power required by the aircraft. This conversion is crucial for operating various electrical systems on the aircraft.
-
Stable Power Supply: They provide a steady and regulated DC power output, essential for properly functioning sensitive electronic systems on the aircraft.
-
Maintenance and Testing: During maintenance and testing, solid-state rectifiers ensure that the aircraft's systems receive the correct type of power, allowing technicians to perform accurate diagnostics and repairs.
Learn More About Aircraft Electrical Power Systems
Frequently Asked Questions: Aircraft Electrical Power Systems
If you have questions about our aircraft electrical power systems, check out the answers to our most frequently asked questions below.